Sale

Thermo Scientific™ PH111 pH/mV Bench Meter

฿180,000.00 ฿170,000.00

Availability: In Stock

SKU: PH111.

Lab Star PH111 pH bench meters measure pH or ORP with mV and temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space.

  1. Range (pH) -2 to 18
  2. Accuracy (pH) ±0.005
  3. Range (mV) ±2000 mV
  4. Accuracy (mV) ±0.2% or ±0.05% (Whichever is Greater)
  5. Temperature Range (Metric) -5°C to +105°C
  6. Resolution (Temperature) 0.1°C (0.1°F)
  7. Temperature Selection Manual, Automatic
หมวดหมู่:

PH111 pH Meter Features

  • Budget-friendly pH meter for simplified pH and ORP testing
  • Display shows pH, mV and temperature simultaneously for accurate data recording
  • Measure -2 to 18 pH, -2000 to +2000 mV and -5 to 105 °C or 23 to 221 °F to ensure comprehensive measurement capabilities
  • Perform one to five point pH calibrations, one point ORP calibrations and one point temperature adjustment calibrations for proficient SOP compliance
  • Large 5 inch backlit display makes viewing and recording measurements easy
  • Small meter footprint saves valuable bench space in your lab
  • Onscreen stabilizing and ready indicators help identify when readings are complete
  • pH electrode condition icon helps ensure reliable electrode performance
  • Date and time data stamped data and calibration logs support GLP compliance
  • View active pH, ORP and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements
  • Use 500-point data log with date and time stamp to record key measurements
  • Output data and calibration logs to a printer or computer for long-term data storage
  • Interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

 

Specification

  • pH range –2.000-18.000 pH
  • pH resolution 0.1, 0.01, 0.001 pH
  • pH accuracy ±0.005 pH ±1 LSD (relative)
  • pH calibration 1 – 5 points
  • mV range ±2000 mV (mV/ORP)
  • mV resolution 0.1 mV (mV/ORP)
  • mV accuracy ±0.2 mV or ±0.05 % of the reading, whichever is greater (mV/ORP, relative)
  • mV calibration 1 point (mV/ORP)
  • Temperature range −5.0…105.0 °C (23.0…221.0 °F)
  • Temperature resolution 0.1 °C, 0.1 °F
  • Temperature accuracy ±0.3 °C, ±0.5 °F (relative)
  • Temperature calibration 1 point
  • Outputs Computer or printer
  • Display 5″ backlit LCD
  • Power supply 100 – 240 VAC, 50 – 60 Hz, 9 DC adapter, 1.3 A
  • W×D×H (mm) 155.2×198.3×61.7
  • Weight 700 g (1.54 lbs.)
  • Data logging – log function 500 sets with time and date
  • Memory Non-volatile
  • IP rating IP-54
  • Alarm Yes, 1 – 168 hours or off (calibration alarm)
  • Input BNC, ATC
  • Calibration Automatic buffer recognition with manual buffer entry option

ติดต่อ บริษัท นีโอนิคส์ โทร 098-479-5684 หรือ 061-8268939 Line ID: @neonics Email:sale@neonics.co.th